UPS25ER

EOL - PC/104 UPS with Power Management & NiMH/NiCd Charger
Product phased out. Please call systerra for replacement options.

The UPS25ER is a flexible PC/104 uninterruptible power supply subsystem that is designed to work together with the RTD XPWR104 power supply Peripheral Module to form a reliable power supply system. This scheme will allow main power interruption up to 30 minutes at 20 Watts while still maintaining complete computer operation.

The main input is rated from 10 to 40 VDC for the UPS25ER unit. While the supply is over 10 V the UPS25ER will charge the local backup NiMH/NiCd battery pack using one of the available charging modes. These charge modes are automatically controlled by the onboard charger circuitry. The charging of the batteries can be enabled from your application software. Additionally, the software can interrogate the UPS status and power states at any time. The UPS25 routes power to your power supply module from either the main input or from the backup battery during main input power failure. An interrupt can be generated when the main power fails, and there is also a status bit that will indicate a soon-to-be discharged battery.

The UPS25ER features a unique shutdown mode where your application software can disconnect the UPS battery after it is ready to shut down. After the UPS25ER is put to sleep the backup battery is disconnected to save the backup battery from being unnecessarily discharged. The charging unit on the UPS25ER ensures that maximum battery life is achieved. The onboard NiMH/NiCd charger accepts 8 batteries with a maximum capacity of 1500 mAh. The nominal full battery voltage is approximately 11.5 V while a completely discharged battery pack will give 7.5 V. Battery temperature is used to terminate the charge process as well as to protect the battery from being charged outside the recommended charge temperature range of 0 to +40C. NiMH batteries will provide backup in the temperature range of -10 to +65C while NiCd batteries will provide backup -20...+65°C range. The standard UPS25ER is delivered without a battery pack, but with a 10K thermistor allowing the construction of custom configured battery units. Starter kits are available with 1500 mAh NiMH or 1000 mAh NiCd battery pack equipped with a 10K NTC thermistor. Please contact systerra for more details on available options.

Features
  • PC/104 Form Factor
  • Complete battery backup system for embedded computers
  • Wide input range 10...40 VDC
  • Charger current limited to 1.2 A
  • Battery output voltage +9.6 V nominal
  • Adjustable backup voltage trip level
  • Charger modes: Fast charge, Top off charge, and Trickle charge
  • Battery temperature and voltage condition monitoring
  • Two charger Status LEDs
  • Software controlled charger operation and diagnostics
  • Disconnects battery and power after shutdown
  • Fully PC/104 compliant


Available in a stackable, rugged IDAN enclosure: IDAN-UPS25
Ordering Options
Manuf. Part No    Part Description
UPS25ER-1  NiMH Charger Peripheral Module
UPS25ERTX-1  UPS25ER-1 configured for use in IDAN Frame
UPS25ER-2  NiCD Charger Peripheral Module
UPS25ERTX-2  UPS25ER-2 configured for use in IDAN Frame
SK-UPS25ER-1  NiMH Charger with 8 AA 1500 mAh cell pack
SK-UPS25ER-2  NiCD Charger with 8 AA 1000 mAh cell pack

Accessories
Manuf. Part No    Part Description
AC/DC PS  AC to DC Power Converter for use with RTD DC/DC Modules
BAT-NiMH  NiMH Battery Pack for use with UPS25ER-2 Peripheral Modules
BAT-NiCd  NiCd Battery Pack for use with UPS25ER-2 Peripheral Modules
Zubehör // Accessories to TOP
AC/DC PS

RTD
AC/DC PS Converter AC to DC Power Converter for use with RTD DC/DC Modules
AC to DC Power Converter for use with RTD DC/DC Modules more
BAT-NiMH

RTD
BAT-NiMH NiMH Battery Pack for use with UPS25ER-2 Peripheral Modules EOL - NiMH Battery Pack for use with UPS25ER-2 Peripheral Modules
Product phased out. Please call systerra for replacement options.

NiMH Battery Pack for use with UPS25ER-2 Peripheral Modules... more
BAT-NiCd

RTD
BAT-NiCd NiCd Battery Pack for use with UPS25ER-2 Peripheral Modules EOL - NiCd Battery Pack for use with UPS25ER-2 Peripheral Modules
Product phased out. Please call systerra for replacement options.

NiCd Battery Pack for use with UPS25ER-2 Peripheral Modules... more
Return to last Page ...